Search results for "ESR dosimetry"
showing 10 items of 19 documents
EXPOSURE OF Gd2O3-ALANINE AND Gd2O3-AMMONIUM TARTRATE ESR DOSIMETERS TO THERMAL NEUTRONS: EXPERIMENTS AND MONTE CARLO SIMULATIONS
2008
Sensitivity of alanine dosimeters with gadolinium exposed to 6 MV photons at clinical doses.
2011
In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on …
Fricke gel, electron spin resonance and thermoluminescence for integration and intercomparison of measurements in NCT dosimetry
2014
Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy.
2017
We report a study of the dosimetric features of phenolic compounds for applications in radiation therapy dosimetry of clinical photon beams by using ESR spectroscopy. After the optimization of the ESR readout parameters, basic dosimetric properties (such as intra-batch reproducibility, dose-response, sensitivity, linearity, dose rate dependence, tissue-equivalence and signal stability) of laboratory-made phenolic dosimeters in form of pellets were investigated. Furthermore, these dosimeters were tested for measuring the depth dose profile of a 6 MV clinical photon beam. The results reported show that these dosimeters are promising materials for ESR dosimetric applications in radiation thera…
Improvement of ESR dosimetry for thermal neutron beams through the addition of gadolinium.
2007
In this paper, the addition of gadolinium is proposed as a useful tool to enhance the electron spin resonance (ESR) sensitivity of organic compounds to thermal neutrons. The target of this work is the detection, through the ESR technique, of the thermal neutron fluence in a mixed field of photons and neutrons. Gadolinium was chosen because it has a very high capture cross section to thermal neutrons; its nuclear reaction with thermal neutrons induces complex inner shell transitions that generate, besides other particles, Auger electrons, which in turn release their energy in the neighborhood (only several nanometers) of the place of reaction. Gadolinium was added to two organic molecules: a…
Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field
2007
In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…
Neutron ESR dosimetry through ammonium tartrate with low Gd content.
2014
This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy rele…